Protocol 122 of 81Layer 7FrameAssembly v3.3.0
Raw .mdllms-full.txt
rocplusEmerson Fisher ROC Plus Oil & Gas Pipeline RTU Protocol

rocplus — Port 4000 Emerson ROC Plus Oil & Gas Pipeline RTUs

Default Port / Protocol
TCP 4000 (or UDP 4000 via transport udp)
Host Endpoint Rule
Dual-Stack IPv4/IPv6
Wireshark Display Filter
tcp.port == 4000 || udp.port == 4000
Standards & Specs
Emerson Fisher ROC Plus Protocol Specifications Manual (D301151X012)
Wire Stack:Ethernet II[802.1Q / QinQ / MPLS]IPv4 / IPv6TCP 4000 (or UDP 4000 via transport udp) (transport tcp|udp)Emerson ROC Plus
L2 Tagging: vlan · qinq · repeatable mpls · fcsHost Family: Dual-Stack IPv4/IPv6L3 QoS & TTL: ttl · dscp · ecnL4 State: transport tcp|udp|sctp (default tcp)

What It Does on the Wire

Wellhead and natural-gas custody-transfer RTUs speak Emerson ROC Plus on port 4000 — rocplus packs unit/group addressing, TLP (type, addr, param) point reads/writes, and reflected CRC-16 trailers.

Emerson Fisher ROC Plus (rocplus) is a core upstream wellhead, custody-transfer flow computer (FloBoss), and midstream natural-gas/crude pipeline RTU (ROC800, FB1000/FB2000) SCADA protocol on TCP or UDP port 4000. Every ROC Plus frame consists of a 6-byte Header (Destination Unit/Destination Group, Source Unit/Source Group, Opcode, and Data Length), Type-Length-Parameter (TLP: Point Type, Logical/Point Number addr, Parameter Number param) data bytes, and a trailing little-endian reflected 16-bit CRC-16 (poly 0xa001, init 0x0000).

FrameAssembly computes Data Length and the trailing ROC CRC-16 (0xa001) automatically (or lets you override crc to test pipeline SCADA gateway error counters).

01. Application

Pipeline Control-Room <-> Wellhead RTU Firewall & TSA Directive Audits

Validate pipeline OT firewalls and IDS sensors (Dragos, Claroty, Nozomi) permitting SCADA polling (rocplus read Opcode 180) on TCP/UDP 4000 while alerting on TLP parameter writes (rocplus write Opcode 181).

02. Application

Custody-Transfer Flow Computer (TLP Point/Parameter) Polling Labs

Craft type / addr / param TLP triples (such as Analog Input type 3, Orifice Meter Run, or System Variables) for Autosol, CygNet, or OpenEnterprise SCADA driver testing.

03. Application

Satellite / Cellular VSAT Low-Bandwidth UDP (transport udp) Testing

Test ROC Plus over both persistent TCP 4000 circuits and low-overhead cellular/VSAT UDP 4000 (transport udp) links.

Fig. 1 · RFC Octet & Bit Schematic

RFC Wire Header Layout (rocplus)

Select any 32-bit wire word or field slice below to inspect which .frasm modifiers control those octets and what defaults the compiler writes.

0 ··············· 15 · 16 ··············· 31 bit
Selected Wire Segment
Emerson ROC Plus Wire PDU & Payload (Variable)
Controlling .frasm Modifiers
rocplus read · dst · type · value · crc · payload · hexpayload
Compiler Default Behavior
RFC-compliant Emerson ROC Plus defaults (Emerson Fisher ROC Plus Protocol Specifications Manual (D301151X012))

Minimal Quickstart (rocplus_quickstart.frasm)

Select Preview Packets to compile in-browser and inspect timestamps + wire byte lengths, or open directly in the Playground.

rocplus_quickstart.frasm10 lines
Open in Playground
host cygnet_host { ip 10.40.1.10 }
host roc800_rtu { ip 10.40.20.1 }
compile {
cygnet_host -> roc800_rtu tcp syn srcport 54000 dstport 4000 wait 1ms
cygnet_host <- roc800_rtu tcp syn ack wait 1ms
cygnet_host -> roc800_rtu tcp ack wait 1ms
cygnet_host -> roc800_rtu rocplus read dst 1 group 2 src 3 type 3 addr 0 param 14 wait 5ms
cygnet_host <- roc800_rtu rocplus read isresponse dst 3 group 0 src 1 type 3 addr 0 param 14 value 850
}

Handled Automatically on the Wire

  • Defaults to stateful TCP port 4000 (transport udp switches to UDP 4000) and calculates byte 5 (Data Length) automatically.
  • Maps read to ROC Plus Opcode 180 (Single/Multiple TLP Read), write to Opcode 181 (TLP Write), and error to Opcode 255 (Error Indicator).
  • Appends the exact 2-byte little-endian reflected ROC CRC-16 (0xa001, init 0x0000) over Header + Data unless crc is overridden.
Multi-Frame Example

Midstream Pipeline Station Poll: ROC800 Analog Pressure TLP Read, Valve Setpoint Write & Error Response

Polls discharge pressure TLP (3, 0, 14) on ROC800 Unit 1 Group 2, writes a regulator setpoint (Opcode 181), and tests an invalid-TLP error response (Opcode 255).

rocplus_pipeline_rtu_tlp.frasm17 lines
Open in Playground
host pipeline_scada { ip 172.23.40.5 }
host station_roc800 { ip 172.23.40.101 }
compile {
pipeline_scada -> station_roc800 tcp syn srcport 52400 dstport 4000 wait 1ms
pipeline_scada <- station_roc800 tcp syn ack wait 1ms
pipeline_scada -> station_roc800 tcp ack wait 1ms
// 1. Opcode 180: Read 1 TLP parameter (Point Type 3 Analog Input, Point 0, Param 14 Filtered EU)
pipeline_scada -> station_roc800 rocplus read dst 1 group 2 src 10 type 3 addr 0 param 14 wait 6ms
pipeline_scada <- station_roc800 rocplus read isresponse dst 10 group 0 src 1 type 3 addr 0 param 14 value 1120 wait 15ms
// 2. Opcode 181: Write TLP Setpoint (Point Type 4 Analog Output, Point 0, Param 2)
pipeline_scada -> station_roc800 rocplus write dst 1 group 2 src 10 type 4 addr 0 param 2 value 950 wait 6ms
pipeline_scada <- station_roc800 rocplus write isresponse dst 10 group 0 src 1 wait 10ms
// 3. Out-of-range TLP poll triggering ROC Error Indicator (Opcode 255)
pipeline_scada -> station_roc800 rocplus read dst 1 group 2 src 10 type 99 addr 99 param 99 wait 6ms
pipeline_scada <- station_roc800 rocplus error isresponse dst 10 group 0 src 1
}
Terminal Commands (FrameAssembly CLI v3.3.0)
# 1. Eyeball relative timestamps, ports & wire lengths in your terminal
frameassembly show rocplus_pipeline_rtu_tlp.frasm

# 2. Compile .frasm -> classic .pcap, nanosecond .pcapng, or pipe via '-'
frameassembly rocplus_pipeline_rtu_tlp.frasm rocplus_pipeline_rtu_tlp.pcap
frameassembly rocplus_pipeline_rtu_tlp.frasm rocplus_pipeline_rtu_tlp.pcapng

# 3. Round-trip .pcap <-> .frasm whenever you want to scrub or tweak an existing capture
frameassembly reverse rocplus_pipeline_rtu_tlp.pcap rocplus_pipeline_rtu_tlp_edited.frasm

# 4. Verify dissected protocol fields in tshark
tshark -r rocplus_pipeline_rtu_tlp.pcap -Y "tcp.port == 4000 || udp.port == 4000"

All rocplus Keywords & Header Options

Every sub-keyword and header option is lowercase [a-z0-9]+ with zero underscores — mix and match them in any order after rocplus:

src_host -> dst_host rocplus [read | write | error | opcode "<text_or_num>" | func "<text_or_num>"] [dst <0..255>] [group <0..255>] [src <0..255>] [type <0..255>] [addr <0..255>] [param <0..255>] [value <number>] [isresponse] [crc <0..65535>] [transport <tcp|udp>]
Keyword / OptionAccepted ValueDefaultEffect on Packet
read | write | error | opcode "<text_or_num>" | func "<text_or_num>" | [isresponse]8-bit ROC Plus Opcode (180 Read TLP, 181 Write TLP, 7 Read Clock, 8 Set Clock, 17 Logon, 255 Error)read (Opcode 180)Sets byte 4 (Opcode) of the 6-byte ROC Plus header and formats request vs isresponse TLP payloads.
dst <0..255> | group <0..255> | src <0..255>8-bit ROC Unit Address (dst, src) & Device Group (group)dst 1, group 2, src 3Writes bytes 0..3 (ROC Unit, ROC Group, Host Unit, Host Group) of the ROC Plus header.
type <0..255> | addr <0..255> | param <0..255>3-byte ROC TLP (Point Type, Logical/Point Number, Parameter Number)type 3, addr 0, param 0Encodes the 3-octet (Type, Location/Number, Parameter) tuple identifying a specific RTU variable.
value <number>32-bit little-endian TLP parameter value0Writes the 4-byte value inside write (181) requests or read isresponse (180) replies.
crc <0..65535> | transport <tcp|udp>Optional 16-bit ROC CRC-16 override & L4 transportAuto 0xa001 CRC-16, transport tcpOverrides the trailing 2-byte little-endian CRC-16 or switches between TCP 4000 and UDP 4000.

Cross-Layer Wrappers Valid with rocplus

802.1Q VLAN / QinQ / MPLS tags, IPv4/IPv6 QoS & TTL fields, wait gaps, and transport overrides allowed on this protocol

15 options
OptionRange / FormatDefaultEffect on Packet
wait <number><ns|us|ms|s|m>Time gap (ns, us, ms, s, m)10msAdvances the packet timestamp clock after sending this packet and before the next packet (wait 0ns sends back-to-back).
comment "<text>"Quoted UTF-8 annotationOmittedAttaches an Enhanced Packet Block opt_comment annotation when compiling to .pcapng (Wireshark pkt_comment filter).
payload "<text>" | hexpayload "<hex>"Quoted text or hex bytes (choose one)OmittedAppends or overrides raw payload bytes ("deadbeef", "de:ad:be:ef", or "\x01\x02") and updates packet lengths and checksums.
srcmac <mac> | dstmac <mac> | ethertype <0..65535>Colon/hyphen/Cisco MAC · EtherType 0..65535 (e.g. 0x0800)Host MAC / RFC multicast MAC / auto EtherTypeOverrides the 14-byte Ethernet II source MAC, destination MAC, or standalone Layer 2 16-bit EtherType.
fcs | badfcsEthernet CRC-32 trailer flags (choose one)Omittedfcs appends a valid IEEE 802.3 4-byte CRC-32 Frame Check Sequence trailer; badfcs XOR-corrupts the CRC-32 for NIC/tap negative tests.
vlan <0..4095> [pcp <0..7>] [dei <0|1>]VLAN ID 0..4095, PCP 0..7, DEI 0..1UntaggedWraps the packet in an IEEE 802.1Q VLAN tag (0x8100) with optional 802.1p QoS priority.
qinq <0..4095> [innervlan <0..4095>]Outer S-VLAN 0..4095, Inner C-VLAN 0..4095Untagged (innervlan 1 when qinq is set)Double-tags the packet with outer IEEE 802.1ad S-Tag (0x88a8) plus inner IEEE 802.1Q C-Tag (0x8100).
mpls <0..1048575> [label <0..1048575>] [exp|tc <0..7>] [bos <0|1>] [mplsttl <0..255>]Repeatable label stack (0..1048575, exp/tc 0..7, bos 0..1, ttl 0..255)Unlabeled (auto bos=0 on outer labels, bos=1 on bottom)Prepends one or more 32-bit MPLS label shims (0x8847, e.g. mpls 16000 mpls 24010) ahead of Layer 2 EoMPLS or Layer 3 payloads.
ttl <0..255> [dscp <0..63>] [ecn <0..3>]TTL/Hop Limit 0..255, DSCP 0..63, ECN 0..3ttl 64, dscp 0, ecn 0Sets IPv4 TTL or IPv6 Hop Limit plus DiffServ (DSCP) and ECN QoS markings.
ipid <0..65535> [df] [mf] [fragoffset <0..8191>] [routeralert] [badipchecksum]IPv4 ID, DF/MF flags, offset 0..8191, Router Alert & checksum faultipid 1, flags 0, fragoffset 0, valid RFC 1071 checksumSets IPv4 Identification/fragmentation, injects RFC 2113 Router Alert (20 04 00 00), or corrupts the 16-bit IPv4 header checksum (badipchecksum).
flowlabel <0..1048575>20-bit IPv6 Flow Label (0..1048575)0Sets the 20-bit IPv6 Flow Label for ECMP routing tests (valid on IPv6 endpoint pairs only).
srcport <0..65535> | dstport <0..65535>Port number 0..65535srcport 49152 (remembered), TCP 4000 (or UDP 4000 via transport udp)Overrides source or destination port and remembers the port pair automatically on <- replies.
transport <tcp|udp|sctp>tcp, udp, or sctp (dual TCP/UDP + universal L7 SCTP)transport tcpSwitches Layer 4 transport between stateful TCP, connectionless UDP, or Castagnoli CRC-32c SCTP association.
badchecksum | nochecksumL4 checksum fault or UDP zero-checksum flagValid RFC checksum / CRC-32cbadchecksum corrupts the L4 checksum for negative firewall/NIC offload tests; nochecksum writes 0x0000 in UDP headers.
seq <number> | acknum <number> | win|window <0..65535> | urgent <0..65535> | syn | ack | psh | fin | rst | urg | ece | cwrTCP sequence/ack numbers, window, flags, SACK, TCP-MD5 & TFO optionspsh ack, win 65535, automatic TCP seq/acknumWhen using TCP (transport tcp or default TCP): overrides automatic TCP sequence tracking, flags, or mss/wscale/sackperm/sackblock/tsval/tsecr/tcpmd5/tfo.

Gotchas & Quick Fixes

Swap dst and src Unit Addresses and Add isresponse on RTU Replies

Valid v3.3.0 Syntax
host_scada -> rtu rocplus read dst 1 group 2 src 10 type 3 addr 0 param 14 host_scada <- rtu rocplus read isresponse dst 10 group 0 src 1 type 3 addr 0 param 14 value 500

In ROC Plus, the replying RTU echoes the same Opcode (180 on Read) while swapping (Unit, Group) addresses and returning the TLP data bytes (isresponse).

ROC Plus Addresses (dst, group, src, type, addr, param) Are 8-Bit (0..255)

Rejected
host_scada -> rtu rocplus read dst 300
Valid v3.3.0 Syntax
host_scada -> rtu rocplus read dst 1 group 2 src 10

ROC unit/group and TLP coordinates are single octets (0..=255); combine dst (Unit) and group (Group) to address up to 65,000 RTUs.

Field Guide 03
Poke Stateful Firewalls, Suricata, Zeek & OT Conduits