Layer 7 Industrial Control Systems & SCADA/OT

Validating Purdue-model OT conduit firewalls, Claroty/Dragos/Nozomi passive ICS sensors, or Suricata SCADA signatures against live PLCs and substation RTUs is never acceptable in production. FrameAssembly synthesizes all 6 flagship industrial protocols (modbus, bacnet, dnp3, s7comm, ethernetip, and opcua) completely offline.

Every industrial builder computes mandatory binary framing and integrity checks automatically—including 7-byte Modbus MBAP lengths, reflected IEEE 1815 0x3d65 per-chunk DNP3 CRCs, RFC 1006 TPKT + ISO 8073 COTP headers on Siemens S7comm, ODVA CIP session/I/O encapsulation, and little-endian IEC 62541 OPC UA chunk sizes.

Keywords in Category 08:modbusbacnetdnp3s7commethernetipopcua
Wire & Endpoint Rules

Wire Framing & Endpoint Rules for Industrial ICS & SCADA/OT

Rule 01

Modbus Request vs. isresponse Framing

modbus defaults to TCP 502 (transport udp uses UDP 502); add isresponse on <- PLC replies so read function codes emit byte-count + register data instead of request addr/count fields.

Rule 02

Automatic Per-Block IEEE 1815 DNP3 CRC-16

dnp3 (0x0564 start bytes, TCP/UDP 20000) calculates reflected 0x3d65 CRC-16 over both the 10-byte Data Link header and every 16-byte user-data block (or accepts explicit crc <u16> for negative tests).

Rule 03

TPKT + COTP Iso-on-TCP for Siemens S7comm

s7comm wraps every 0x32 Job / Ack-Data PDU in valid 4-byte TPKT (03 00 len) + 3-byte COTP DT (02 f0 80) headers on stateful TCP 102.

Rule 04

Explicit TCP 44818 vs. Implicit UDP 2222 CIP

ethernetip uses TCP 44818 for explicit registersession / sendrrdata messaging and switches automatically to UDP 2222 on sendunitdata (or transport udp).

Multi-Protocol Capture Example

Purdue Conduit Audit: Modbus Read/Write, DNP3 Operate, S7comm & OPC UA

Tests an OT cell-zone conduit with a stateful TCP 502 Modbus holding-register read + blocked single-coil write, a UDP 20000 IEEE 1815 DNP3 Select/Operate pair with auto CRC-16, a UDP 47808 BACnet Who-Is, and a TCP 4840 OPC UA Hello/Acknowledge handshake.

ot_ics_conduit_audit.frasm19 lines
Open in Playground
host hmi_eng { ip 10.100.10.20 }
host plc_rtu { ip 10.100.20.50 }
compile {
hmi_eng -> plc_rtu tcp syn srcport 50502 dstport 502 win 65535 mss 1460 wait 1ms
hmi_eng <- plc_rtu tcp syn ack win 65535 mss 1460 wait 1ms
hmi_eng -> plc_rtu tcp ack wait 1ms
hmi_eng -> plc_rtu modbus readholdingregisters txid 1 unitid 1 addr 100 count 4 wait 2ms
hmi_eng <- plc_rtu modbus readholdingregisters isresponse txid 1 unitid 1 count 4 wait 2ms
hmi_eng -> plc_rtu modbus writesinglecoil txid 2 unitid 1 addr 10 value 0xff00 wait 3ms
hmi_eng -> plc_rtu dnp3 select transport udp src 1 dst 10 group 12 variation 1 wait 2ms
hmi_eng -> plc_rtu dnp3 operate transport udp src 1 dst 10 group 12 variation 1 wait 2ms
hmi_eng -> plc_rtu bacnet whois wait 2ms
hmi_eng -> plc_rtu tcp syn srcport 50840 dstport 4840 win 65535 mss 1460 wait 1ms
hmi_eng <- plc_rtu tcp syn ack win 65535 mss 1460 wait 1ms
hmi_eng -> plc_rtu tcp ack wait 1ms
hmi_eng -> plc_rtu opcua msgtype "HEL" chunktype "F" endpointurl "opc.tcp://10.100.20.50:4840" wait 1ms
hmi_eng <- plc_rtu opcua msgtype "ACK" chunktype "F"
}
Terminal Commands (FrameAssembly CLI v3.2.2)
# 1. Eyeball relative timestamps, ports & wire lengths in your terminal
frameassembly show ot_ics_conduit_audit.frasm

# 2. Compile .frasm -> classic .pcap (tcpdump/tcpreplay/Suricata) or nanosecond .pcapng
frameassembly ot_ics_conduit_audit.frasm ot_ics_conduit_audit.pcap
frameassembly ot_ics_conduit_audit.frasm ot_ics_conduit_audit.pcapng

# 3. Round-trip .pcap <-> .frasm whenever you want to scrub or tweak an existing capture
frameassembly reverse ot_ics_conduit_audit.pcap ot_ics_conduit_audit_edited.frasm

# 4. Verify dissected protocol fields in tshark
tshark -r ot_ics_conduit_audit.pcap -Y "mbtcp || dnp3 || bacnet || opcua"
All 6 Protocols

All 6 Native Protocols in Layer 7 Industrial Control Systems & SCADA/OT

Select any lowercase protocol keyword below for its full RFC wire layout, modifier table, cross-layer wrappers, and runnable lab capture.

#KeywordProtocol & Wire SummaryDefault Port / ProtoEndpoint RuleWireshark Filter
76modbusModbus TCP / UDP Industrial Application Protocol

modbus — Port 502 MBAP Register Reads & Coil Write Audits

TCP 502 (or UDP 502 via transport udp)Dual-Stack IPv4/IPv6mbtcp || modbus
77bacnetBACnet/IP Building Automation & Control Networks

bacnet — UDP 47808 (0xbac0) BMS Who-Is & Property Frames

UDP 47808 (0xbac0)Dual-Stack IPv4/IPv6bacnet || bvlc || bacapp
78dnp3Distributed Network Protocol 3 (Electric & Water Utilities)

dnp3 — Substation RTU Commands & Automatic Per-Chunk CRC-16

TCP 20000 (or UDP 20000 via transport udp)Dual-Stack IPv4/IPv6dnp3
79s7commSiemens S7 Communication Protocol over ISO-on-TCP

s7comm — Port 102 TPKT/COTP Siemens S7 Reads, Writes & Stop

TCP 102 (ISO-on-TCP)Dual-Stack IPv4/IPv6s7comm
80ethernetipODVA EtherNet/IP & Common Industrial Protocol (Rockwell)

ethernetip — Rockwell CIP Sessions (44818) & UDP 2222 I/O

TCP 44818 (Explicit) / UDP 2222 (Implicit I/O)Dual-Stack IPv4/IPv6enip || cip
81opcuaOPC Unified Architecture Binary TCP Protocol

opcua — Port 4840 Purdue-DMZ Binary Chunks (HEL/ACK/OPN/MSG)

TCP 4840Dual-Stack IPv4/IPv6opcua