# modbus — Port 502 MBAP Register Reads & Coil Write Audits (`modbus`)

> **FrameAssembly v3.2.2** · Protocol 76 of 81 · Canonical URL: https://frameassembly-lang.dev/docs/protocols/modbus

- **Full Protocol Name:** Modbus TCP / UDP Industrial Application Protocol
- **Keyword:** `modbus`
- **OSI Layer & Transport:** Layer 7 · TCP 502 (or UDP 502 via transport udp)
- **Host Endpoint Rule:** Dual-Stack IPv4/IPv6
- **Standards:** Modbus Application Protocol v1.1b3
- **Wireshark Display Filter:** `mbtcp || modbus`
- **Wire Encapsulation:** `Ethernet II -> [802.1Q / QinQ / MPLS] -> IPv4 / IPv6 -> TCP 502 (or UDP 502 via transport udp) (transport tcp|udp) -> Modbus TCP`

## Overview

Modbus has zero authentication: anyone who can reach TCP `502` can flip coils. Craft `readholdingregisters` (`FC 3`), `writesinglecoil` (`FC 5`), and `isresponse` PLC replies offline without making the plant manager sweat.

Modbus TCP (`modbus`) is the most widely deployed industrial protocol connecting SCADA HMIs, historians, VFDs, smart breakers, and PLCs over **TCP port `502`** (with `transport udp` available for Modbus-over-UDP gateways). Because Modbus has **zero built-in authentication**, industrial firewalls (Palo Alto, Fortinet, Tofino/Hirschmann) and OT IDS platforms (Claroty, Nozomi, Dragos, Suricata, Zeek) inspect every **7-byte MBAP header + Function Code** to allow safe read polling (`FC 1..4`) while alerting on or blocking write commands (`FC 5, 6, 15, 16`).

FrameAssembly builds exact MBAP headers (`txid`, `protoid 0`, `length`, `unitid`) and Modbus request or PLC reply (`isresponse`) PDUs completely offline—without ever touching live plant equipment.

## Minimal Quickstart (`modbus_quickstart.frasm`)

```frameassembly
host scada_hmi { ip 192.168.100.10 }
host plc_pump1 { ip 192.168.100.50 }

compile {
    scada_hmi -> plc_pump1 tcp syn srcport 50502 dstport 502 wait 1ms
    scada_hmi <- plc_pump1 tcp syn ack wait 1ms
    scada_hmi -> plc_pump1 tcp ack wait 1ms
    scada_hmi -> plc_pump1 modbus readholdingregisters txid 1 unitid 1 addr 100 count 2 wait 3ms
    scada_hmi <- plc_pump1 modbus readholdingregisters txid 1 unitid 1 count 2 value 1500 isresponse
}
```

### Automatic Wire Calculations

- Defaults to TCP destination port `502` (`psh ack`), Protocol ID `0`, `unitid 1`, and computes the 16-bit MBAP `Length` (`unitid + PDU bytes`) automatically.
- Formats client Request PDUs (`addr` + `count` / `value`) by default, and switches to PLC Response PDUs (`byte_count` + register/coil values) when `isresponse` is set.
- Translates `writesinglecoil value 1` into the standard Modbus `0xff00` (`ON`) coil value automatically.

## Practical Lab Example: Normal Historian Read Polling (`FC 3`) + Unauthorized Coil/Register Write (`FC 5` / `FC 6`) (`modbus_ot_conduit_test.frasm`)

Models an HMI polling Holding Registers on Unit 1 (`FC 3` request + `isresponse` reply), followed by a `writesinglecoil` (`FC 5`) and `writesingleregister` (`FC 6`) command to test OT write-detection alarms.

```frameassembly
host hmi_01   { ip 10.100.10.15 }
host vfd_plc  { ip 10.100.20.50 }

compile {
    hmi_01 -> vfd_plc tcp syn srcport 51502 dstport 502 win 65535 mss 1460 wait 1ms
    hmi_01 <- vfd_plc tcp syn ack win 65535 mss 1460 wait 1ms
    hmi_01 -> vfd_plc tcp ack wait 1ms
    // 1. Authorized Read Holding Registers (FC 3) + PLC Response (isresponse)
    hmi_01 -> vfd_plc modbus readholdingregisters txid 101 unitid 1 addr 0 count 4 wait 2ms
    hmi_01 <- vfd_plc modbus readholdingregisters txid 101 unitid 1 count 4 value 3600 isresponse wait 5ms
    // 2. Write Single Coil (FC 5) & Write Single Register (FC 6) -> triggers OT IDS write alert!
    hmi_01 -> vfd_plc modbus writesinglecoil txid 102 unitid 1 addr 10 value 1 wait 2ms
    hmi_01 <- vfd_plc modbus writesinglecoil txid 102 unitid 1 addr 10 value 1 isresponse wait 3ms
    hmi_01 -> vfd_plc modbus writesingleregister txid 103 unitid 1 addr 200 value 1800
}
```

```bash
# 1. Eyeball relative timestamps, ports & wire lengths in your terminal
frameassembly show modbus_ot_conduit_test.frasm

# 2. Compile .frasm -> classic .pcap (tcpdump/tcpreplay/Suricata) or nanosecond .pcapng
frameassembly modbus_ot_conduit_test.frasm modbus_ot_conduit_test.pcap
frameassembly modbus_ot_conduit_test.frasm modbus_ot_conduit_test.pcapng

# 3. Round-trip .pcap <-> .frasm whenever you want to scrub or tweak an existing capture
frameassembly reverse modbus_ot_conduit_test.pcap modbus_ot_conduit_test_edited.frasm

# 4. Verify dissected protocol fields in tshark
tshark -r modbus_ot_conduit_test.pcap
```

## All `modbus` Keywords & Header Options

Packet line pattern: `src_host -> dst_host modbus [readcoils | readdiscreteinputs | readholdingregisters | readinputregisters | writesinglecoil | writesingleregister | writemultipleregisters | func "<name_or_fc>"] [txid <0..65535>] [protoid <0..65535>] [unitid <0..255>] [addr <0..65535>] [count <0..65535>] [value <0..65535>] [isresponse] [transport <tcp|udp>]`

| Keyword / Option | Accepted Value | Default | Effect on Packet |
| --- | --- | --- | --- |
| `readcoils \| readdiscreteinputs \| readholdingregisters \| readinputregisters \| writesinglecoil \| writesingleregister \| writemultipleregisters \| func "<fc>"` | Function Code keyword or number (`"1"`, `"2"`, `"3"`, `"4"`, `"5"`, `"6"`, `"15"`, `"16"`) | `readholdingregisters (FC 3)` | Sets the 1-byte Modbus Function Code immediately after `unitid`. |
| `txid <0..65535> \| protoid <0..65535> \| unitid <0..255>` | MBAP Transaction ID, Protocol ID (`0` = Modbus), and Slave/Unit ID | `txid 1, protoid 0, unitid 1` | Populates the 7-byte MBAP header preceding the Modbus PDU. |
| `addr <0..65535> \| count <0..65535> \| value <0..65535>` | 0-indexed starting register/coil address, item quantity, and write/reply value | `addr 0, count 1, value 0` | Populates register addresses, counts, and 16-bit data words. |
| `isresponse` | Keyword flag on PLC replies | `Request format when omitted` | Formats `FC 1..4` packets as PLC responses (`[FC][ByteCount][Data...]`) so Wireshark dissects the reply without malformed-length warnings. |
| `transport <tcp\|udp>` | `tcp` or `udp` | `tcp` | Switches between Modbus TCP (`502`) and Modbus UDP (`502`). |

## Cross-Layer Options Valid with `modbus`

| Option | Range / Format | Default | Effect |
| --- | --- | --- | --- |
| `wait <number><ns\|us\|ms\|s\|m>` | Time gap (ns, us, ms, s, m) | `10ms` | Advances the packet timestamp clock after sending this packet and before the next packet (`wait 0ns` sends back-to-back). |
| `payload "<text>" \| hexpayload "<hex>"` | Quoted text or hex bytes (choose one) | `Omitted` | Appends or overrides raw payload bytes (`"deadbeef"` or `"de:ad:be:ef"`) and updates packet lengths and checksums. |
| `srcmac <mac> \| dstmac <mac> \| ethertype <0..65535>` | Colon/hyphen/Cisco MAC · EtherType u16 (e.g. 0x0800) | `Host MAC / RFC multicast MAC / auto EtherType` | Overrides the 14-byte Ethernet II source MAC, destination MAC, or 16-bit EtherType for this single packet. |
| `vlan <0..4095> [pcp <0..7>] [dei <0\|1>]` | VLAN ID 0..4095, PCP 0..7, DEI 0..1 | `Untagged` | Wraps the packet in an IEEE 802.1Q VLAN tag (`0x8100`) with optional 802.1p QoS priority. |
| `qinq <0..4095> [innervlan <0..4095>]` | Outer S-VLAN 0..4095, Inner C-VLAN 0..4095 | `Untagged (innervlan 1 when qinq is set)` | Double-tags the packet with outer IEEE 802.1ad S-Tag (`0x88a8`) plus inner IEEE 802.1Q C-Tag (`0x8100`). |
| `mpls <0..1048575> [label <0..1048575>] [exp\|tc <0..7>] [bos <0\|1>] [mplsttl <0..255>]` | Label 0..1048575, exp/tc 0..7, bos 0..1, ttl 0..255 | `Unlabeled (at most 1 mpls tag per packet)` | Inserts a 32-bit MPLS label header (`0x8847`) ahead of the Layer 3 header. |
| `ttl <0..255> [dscp <0..63>] [ecn <0..3>]` | TTL/Hop Limit 0..255, DSCP 0..63, ECN 0..3 | `ttl 64, dscp 0, ecn 0` | Sets IPv4 TTL or IPv6 Hop Limit plus DiffServ (DSCP) and ECN QoS markings. |
| `ipid <0..65535> [df] [mf] [fragoffset <0..8191>]` | IPv4 ID, DF/MF flags, fragment offset 0..8191 | `ipid 1, flags 0, fragoffset 0` | Sets IPv4 Identification, Do-Not-Fragment (`df`), More-Fragments (`mf`), and fragment offset (ignored over IPv6). |
| `flowlabel <0..1048575>` | 20-bit IPv6 Flow Label (0..1048575) | `0` | Sets the 20-bit IPv6 Flow Label for ECMP routing tests (ignored when running over IPv4 hosts). |
| `srcport <0..65535> \| dstport <0..65535>` | Port number 0..65535 | `srcport 49152 (remembered), TCP 502 (or UDP 502 via transport udp)` | Overrides source or destination port and remembers the port pair automatically on `<-` replies. |
| `transport <tcp\|udp>` | `tcp` or `udp` (supported on 9 dual-L4 protocols) | `transport tcp` | Switches Layer 4 transport between TCP (`psh ack` + length framing where required) and UDP. |
| `seq <number> \| acknum <number> \| win\|window <0..65535> \| urgent <0..65535> \| syn \| ack \| psh \| fin \| rst \| urg \| ece \| cwr` | TCP sequence/ack numbers, window size, flags & RFC 7323 options | `psh ack, win 65535, automatic TCP seq/acknum` | When using TCP (`transport tcp` or default TCP): overrides automatic TCP sequence tracking, flags, or `mss`/`wscale`/`sackperm`/`tsval`/`tsecr`. |

## Common Mistakes & Quick Fixes

### Add isresponse on <- PLC Replies to Read Requests (FC 1..4)

- **Avoid:** `scada_hmi <- plc_pump1 modbus readholdingregisters txid 1 count 2 value 1500`
- **Valid v3.2.2 Syntax:** `scada_hmi <- plc_pump1 modbus readholdingregisters txid 1 count 2 value 1500 isresponse`

Modbus uses the same Function Code (`0x03`) for both requests and responses, with different wire layouts. Adding `isresponse` emits the PLC’s `Byte Count + Register Values` reply structure.