# dnp3 — Substation RTU Commands & Automatic Per-Chunk CRC-16 (`dnp3`)

> **FrameAssembly v3.2.2** · Protocol 78 of 81 · Canonical URL: https://frameassembly-lang.dev/docs/protocols/dnp3

- **Full Protocol Name:** Distributed Network Protocol 3 (Electric & Water Utilities)
- **Keyword:** `dnp3`
- **OSI Layer & Transport:** Layer 7 · TCP 20000 (or UDP 20000 via transport udp)
- **Host Endpoint Rule:** Dual-Stack IPv4/IPv6
- **Standards:** IEEE 1815-2012
- **Wireshark Display Filter:** `dnp3`
- **Wire Encapsulation:** `Ethernet II -> [802.1Q / QinQ / MPLS] -> IPv4 / IPv6 -> TCP 20000 (or UDP 20000 via transport udp) (transport tcp|udp) -> DNP3 (IEEE 1815)`

## Overview

Hand-crafting DNP3 usually makes grown engineers cry because IEEE 1815 demands a reflected CRC-16 after the `0x0564` link header *and* every 16 payload bytes — `dnp3` calculates every block CRC automatically (unless you pass `crc 0xdead` to test bad-CRC alarms!).

Distributed Network Protocol 3 (`dnp3`, IEEE 1815) is the primary SCADA telemetry and breaker-control protocol in North American electric substations, solar/wind farms, and water/wastewater utilities on **TCP or UDP port `20000`**. Crafting valid DNP3 packets by hand is notoriously hard because DNP3 inserts a reflected **IEEE 1815 CRC-16 (`0x3d65`, inverted)** after the 8-byte `0x0564` Data Link header **and** after every 16-byte Data Link user-data block.

FrameAssembly calculates every per-block DNP3 CRC-16 automatically (and also lets you override `crc` deliberately if you want to test dissector malformed-CRC handling!).

## Minimal Quickstart (`dnp3_quickstart.frasm`)

```frameassembly
host scada_master { ip 10.100.1.10 }
host sub_rtu_10   { ip 10.100.2.10 }

compile {
    scada_master -> sub_rtu_10 tcp syn srcport 52000 dstport 20000 wait 1ms
    scada_master <- sub_rtu_10 tcp syn ack wait 1ms
    scada_master -> sub_rtu_10 tcp ack wait 1ms
    scada_master -> sub_rtu_10 dnp3 read src 1 dst 10 group 30 variation 1 wait 3ms
    scada_master <- sub_rtu_10 dnp3 response src 10 dst 1 group 30 variation 1
}
```

### Automatic Wire Calculations

- Defaults to TCP destination port `20000` (`transport udp` switches to UDP `20000`) and builds the `0x0564` Data Link + Transport (`FIN|FIR`) + Application headers.
- Computes the reflected IEEE 1815 `0x3d65` CRC-16 across the 8-byte Data Link header and every 16-byte user-data chunk automatically.
- Encodes `src` and `dst` 16-bit DNP3 station addresses in little-endian wire order per IEEE 1815.

## Practical Lab Example: Substation Analog Input Poll (`Group 30`) + Select-Before-Operate (`Group 12` CROB) (`dnp3_substation_sbo.frasm`)

Polls Analog Inputs (`group 30 variation 1`), receives an RTU `unsolicitedresponse` event (`group 2` Binary Input Change), and executes a two-step `select` -> `operate` breaker sequence.

```frameassembly
host ems_master { ip 172.25.1.5 }
host feeder_rtu { ip 172.25.10.20 }

compile {
    ems_master -> feeder_rtu tcp syn srcport 53000 dstport 20000 win 65535 mss 1460 wait 1ms
    ems_master <- feeder_rtu tcp syn ack win 65535 mss 1460 wait 1ms
    ems_master -> feeder_rtu tcp ack wait 1ms
    // 1. Class/Group 30 Analog Input Read + RTU Response
    ems_master -> feeder_rtu dnp3 read src 1 dst 20 group 30 variation 1 wait 3ms
    ems_master <- feeder_rtu dnp3 response src 20 dst 1 group 30 variation 1 wait 10ms
    // 2. RTU Unsolicited Event (Group 2 Binary Input Event) + Master Confirm
    ems_master <- feeder_rtu dnp3 unsolicitedresponse src 20 dst 1 group 2 variation 2 wait 2ms
    ems_master -> feeder_rtu dnp3 confirm src 1 dst 20 wait 5ms
    // 3. Select-Before-Operate (Group 12 Variation 1 CROB) -> triggers high-priority OT alert
    ems_master -> feeder_rtu dnp3 select src 1 dst 20 group 12 variation 1 wait 2ms
    ems_master <- feeder_rtu dnp3 response src 20 dst 1 group 12 variation 1 wait 2ms
    ems_master -> feeder_rtu dnp3 operate src 1 dst 20 group 12 variation 1
}
```

```bash
# 1. Eyeball relative timestamps, ports & wire lengths in your terminal
frameassembly show dnp3_substation_sbo.frasm

# 2. Compile .frasm -> classic .pcap (tcpdump/tcpreplay/Suricata) or nanosecond .pcapng
frameassembly dnp3_substation_sbo.frasm dnp3_substation_sbo.pcap
frameassembly dnp3_substation_sbo.frasm dnp3_substation_sbo.pcapng

# 3. Round-trip .pcap <-> .frasm whenever you want to scrub or tweak an existing capture
frameassembly reverse dnp3_substation_sbo.pcap dnp3_substation_sbo_edited.frasm

# 4. Verify dissected protocol fields in tshark
tshark -r dnp3_substation_sbo.pcap
```

## All `dnp3` Keywords & Header Options

Packet line pattern: `src_host -> dst_host dnp3 [read | write | select | operate | directoperate | confirm | response | unsolicitedresponse | func "<text>"] [src <0..65535>] [dst <0..65535>] [group <0..255>] [variation <0..255>] [crc <hex_or_num>] [transport <tcp|udp>]`

| Keyword / Option | Accepted Value | Default | Effect on Packet |
| --- | --- | --- | --- |
| `read \| write \| select \| operate \| directoperate \| confirm \| response \| unsolicitedresponse \| func "<text>"` | DNP3 Application Function Code | `read (0x01)` | Selects `0x00` Confirm, `0x01` Read, `0x02` Write, `0x03` Select, `0x04` Operate, `0x05` Direct Operate, `0x81` Response, or `0x82` Unsolicited Response. |
| `src <0..65535> \| dst <0..65535>` | 16-bit DNP3 Data Link station addresses | `src 1, dst 10` | Sets the 2-byte little-endian DNP3 Source and Destination outstation/master addresses. |
| `group <0..255> \| variation <0..255>` | DNP3 Object Group (`1` Binary In, `12` CROB, `30` Analog In, `60` Class Data) + Variation | `group 30, variation 1` | Populates the Object Header `(Group, Variation)` inside the Application Layer. |
| `crc <hex_or_num>` | Optional 16-bit link-header CRC override | `Auto-computed IEEE 1815 CRC-16` | Replaces the computed Data Link header CRC for negative/fuzz testing (omit for valid packets!). |
| `transport <tcp\|udp>` | `tcp` or `udp` | `tcp` | Switches Layer 4 between TCP `20000` and UDP `20000`. |

## Cross-Layer Options Valid with `dnp3`

| Option | Range / Format | Default | Effect |
| --- | --- | --- | --- |
| `wait <number><ns\|us\|ms\|s\|m>` | Time gap (ns, us, ms, s, m) | `10ms` | Advances the packet timestamp clock after sending this packet and before the next packet (`wait 0ns` sends back-to-back). |
| `payload "<text>" \| hexpayload "<hex>"` | Quoted text or hex bytes (choose one) | `Omitted` | Appends or overrides raw payload bytes (`"deadbeef"` or `"de:ad:be:ef"`) and updates packet lengths and checksums. |
| `srcmac <mac> \| dstmac <mac> \| ethertype <0..65535>` | Colon/hyphen/Cisco MAC · EtherType u16 (e.g. 0x0800) | `Host MAC / RFC multicast MAC / auto EtherType` | Overrides the 14-byte Ethernet II source MAC, destination MAC, or 16-bit EtherType for this single packet. |
| `vlan <0..4095> [pcp <0..7>] [dei <0\|1>]` | VLAN ID 0..4095, PCP 0..7, DEI 0..1 | `Untagged` | Wraps the packet in an IEEE 802.1Q VLAN tag (`0x8100`) with optional 802.1p QoS priority. |
| `qinq <0..4095> [innervlan <0..4095>]` | Outer S-VLAN 0..4095, Inner C-VLAN 0..4095 | `Untagged (innervlan 1 when qinq is set)` | Double-tags the packet with outer IEEE 802.1ad S-Tag (`0x88a8`) plus inner IEEE 802.1Q C-Tag (`0x8100`). |
| `mpls <0..1048575> [label <0..1048575>] [exp\|tc <0..7>] [bos <0\|1>] [mplsttl <0..255>]` | Label 0..1048575, exp/tc 0..7, bos 0..1, ttl 0..255 | `Unlabeled (at most 1 mpls tag per packet)` | Inserts a 32-bit MPLS label header (`0x8847`) ahead of the Layer 3 header. |
| `ttl <0..255> [dscp <0..63>] [ecn <0..3>]` | TTL/Hop Limit 0..255, DSCP 0..63, ECN 0..3 | `ttl 64, dscp 0, ecn 0` | Sets IPv4 TTL or IPv6 Hop Limit plus DiffServ (DSCP) and ECN QoS markings. |
| `ipid <0..65535> [df] [mf] [fragoffset <0..8191>]` | IPv4 ID, DF/MF flags, fragment offset 0..8191 | `ipid 1, flags 0, fragoffset 0` | Sets IPv4 Identification, Do-Not-Fragment (`df`), More-Fragments (`mf`), and fragment offset (ignored over IPv6). |
| `flowlabel <0..1048575>` | 20-bit IPv6 Flow Label (0..1048575) | `0` | Sets the 20-bit IPv6 Flow Label for ECMP routing tests (ignored when running over IPv4 hosts). |
| `srcport <0..65535> \| dstport <0..65535>` | Port number 0..65535 | `srcport 49152 (remembered), TCP 20000 (or UDP 20000 via transport udp)` | Overrides source or destination port and remembers the port pair automatically on `<-` replies. |
| `transport <tcp\|udp>` | `tcp` or `udp` (supported on 9 dual-L4 protocols) | `transport tcp` | Switches Layer 4 transport between TCP (`psh ack` + length framing where required) and UDP. |
| `seq <number> \| acknum <number> \| win\|window <0..65535> \| urgent <0..65535> \| syn \| ack \| psh \| fin \| rst \| urg \| ece \| cwr` | TCP sequence/ack numbers, window size, flags & RFC 7323 options | `psh ack, win 65535, automatic TCP seq/acknum` | When using TCP (`transport tcp` or default TCP): overrides automatic TCP sequence tracking, flags, or `mss`/`wscale`/`sackperm`/`tsval`/`tsecr`. |

## Common Mistakes & Quick Fixes

### Swap DNP3 src and dst Station Addresses on <- RTU Replies

- **Valid v3.2.2 Syntax:** `master -> rtu dnp3 read src 1 dst 10
master <- rtu dnp3 response src 10 dst 1`

While `<-` automatically flips Ethernet, IP, and TCP ports, DNP3 `src` and `dst` explicitly set the Data Link station fields (`src 10 dst 1` when the RTU replies to Master `1`).

### Omit crc Unless You Intentionally Want a Bad Checksum

- **Valid v3.2.2 Syntax:** `scada_master -> sub_rtu_10 dnp3 read src 1 dst 10`

FrameAssembly calculates the exact IEEE 1815 CRC-16 automatically whenever `crc` is omitted.